Panel Connection - TTL

Manufacturer Texecom
Model Premier
Version 60, 88, 168, 816
Panel Firmware Range V1.x - V10.x
Cable required? Texecom TTL-molex (05-0246)
MCM or Serial Connection Serial
Panel Profile TEXECOM Profile
Panel Bus Connection TTL
Techincal Notes Premier Range is being phased out....

Cable Connection

WebWay Terminal Point Texecom Panel Connection
TTL - T (RED) Com Port 1 Pin 2 from right
TTL - R (Green) Com Port 1 Pin 1 from right
RTN - (Blue) Com Port 1 Pin 3 from right

Pro Unit Connection

Pro Unit Connection

Texecom Cable 05-0246

Texecom Cable 05-0246

Panel Programming

  • Enter Engineer Mode

  • Select Options Menu
  • Enable communicator must be ticked
  • UDL passcode (set in the panel) must match.
  • Dial attempts 1, ring before answer 3

  • In ARC’s
  • Account number (site ID)
  • SIA Level 2/3
  • Connect Via IP - ticked
  • Send SIA text – ticked

  • In Radio-Pad and Com Port Options Menu
  • Under set Com Port 1 to – WebWayOne module
  • Local IP address - 127.0.0.1
  • Local IP port - 50561
  • Gateway - 127.0.0.1
  • Subnet Mask - 255.255.255.0
  • Name/SMG port - 50561

  • Log Out of Engineer Mode to establish electrical connection

Troubleshooting

  • The WebWay should be connected to Com port 1.
  • If only Com port 2 or 3 is available: Make sure the baud rate (modem speed) is set to 19200.
  • WebWay SPT Firmware V3.45 and above
  • If the Texecom is being programmed with a laptop on com port 2, the WebWay is connected to com port 1 the SPT will be lost from the panel until the Wintex session is closed.
  • Only the alarm format SIA is supported.