WebWayWorld Logo 2018

 

Panel Connection - MCM

Manufacturer Honeywell
Model Ademco
Version Vista4249
Panel Firmware Range Rev.17
MCM Plug on required? MCM version less or equal to V1.05 - Needs SPT version less or equal to V2.06
MCM version greater or equal to V1.06 - Needs SPT version greater or equal to V2.07
MCM or Serial Connection MCM
Panel Profile GalaxyDigi CID
Panel Bus Connection None
Technical Notes No UDL Integration for this panel.

Cable Connection

MCM Connection Panel Connection
A Pin 28
B Pin 29

Images

MCM Connection

MCM Connection

SPT and MCM module

SPT and MCM module

Panel Programming

  • *32 Prim Subs ACCT # Site ID
  • *33 Primary Phone Number 01234567890
  • *42 Dial Tone Pause 0
  • *43 Dial Tone Detection 0
  • *44 Ring Detection Count 0
  • *45 Primary Format 1 (Contact ID)
  • *51 Dual Reporting 0
  • *52 Std/Expanded Report for Primary 1 Expanded
  • *99 Exit Menus

Panel Power

  • Positive - Pin 6
  • Negative - Pin 7