WebWayWorld Logo 2018

 

Panel Connection - MCM

Manufacturer Castle / Pyronix
Model Enforcer
Version Enforcer - Wireless
Panel Firmware Range V09.13
MCM Plug on required? MCM version less or equal to V1.05 - Needs SPT version less or equal to V2.06
MCM version greater or equal to V1.06 - Needs SPT version greater or equal to V2.07
MCM or Serial MCM
Panel Profile CASTLEDIGI
Panel Bus Connection None
MCM Firmware Version V1.04
UDL Package Castle (Insite)

Cable Connection

SPT Panel
MCM plug-on module - Line a PSTN Line A
MCM plug-on module - Line b PSTN Line B

Images

SPT and MCM module

SPT and MCM module

SPT and MCM module

SPT and MCM module

Panel Programing

  • Go to Engineering Mode
  • Go to Program ARC/SMS?s
  • Press (YES)
  • Display Shows: ARC/SMS is Dispable
  • Select <0>
  • Press (YES)
  • Display Shows: Active - Yes [1]
  • Press (yes)
  • Display Shows: Active - Yes [1]
  • Press (YES)
  • Select 9Option 129
  • Press (YES)
  • Display Shows: 1st ARC/SMSC
  • Enter <01666111>
  • Press (YES)
  • Display Shows: Second No
  • Enter <01666222>
  • Press (YES)
  • Select Valid areas (A,B,C,D) (to suit your Installation)
  • Press (YES)
  • Display Shows: Area Accounts/ (NO)
  • Press (YES)
  • Select ARC account <****> (this is the ARC Account Number/Chip No)
  • Press (YES)
  • Select content 1-16 (Trigger events) (recommend 1-5 & 7-13)
  • Press (YES)
  • Select content 17-32 (trigger events) (recommend 21-25, 27-30 & 32)
  • Press (YES)
  • Select redials <03>
  • Press (YES)
  • Select redials <03>
  • Press
  • Select test calls (NO)

Remote Access Programming

  • • Go to ‘set up downloading’
  • • Select download by (WebWayOne)
  • • Select poll timeout <10>
  • • Select modem init timeout <060>
  • • Select rings to answer <1>
  • • Select comm. Tx timeout <030>
  • • Select ARMPC telephone number (not required)
  • • Select program PCs <1>
  • • Select signal alarms (No)
  • • Select signal faults (No)
  • • Select signal set/unset (No)
  • • Select signal access code (No)
  • • Select password (optional UDL password)
  • • Select redials <03>
  • • Select time out <00>
  • • Select stop on success (No)
  • • Select dial mode (retry same)
  • • Exit engineering mode and save the configuration

UDL information for this item can be found here: