Model CD range
Version CD72, CD95
Cable required? No
Remote Manager Software Titan
Serial Connection Serial
Panel Profile CD 95 SIA
Panel Bus Connection RS232
Technical Notes Please see below

Cable Connection

Cable WebWay SPT
BLUE RS232 T
RED RS232 R
GREEN RTN

Galaxy Panel Connections

Galaxy Panel Connections

SPT Connections

SPT Connections

Panel Configuration

  • To access the MPI232 settings you will need to connect your PC to the MPI232's DTE serial port. Run up a hyperterminal application (such as putty) set at 9600, None, 8, 1.
  • Set switch 3 on the MPI232 module to OFF.
  • Power up MPI232 module.
  • You will see the following: MPI V2.23 programming main menu
  • 1 - Central station menu
  • 2 - Report options
  • 3 - Protocol options
  • 0 - Exit MPI programming
  • Make your choice:
  • Select 3: Protocol options
  • 1. Modem init string: AT&K0&DE1V1Q0S0=0S7=10
  • 2. Modem dial string: ATD
  • 3. Modem hangup string : ATH
  • 4. Modem connect string :
  • 5. CLID string 1: 00001
  • 6. CLID string 2: 00002
  • 7. Baudrate RS-232 port : 9600
  • 8. Baudrate V31bis port : 9600
  • 0. Back to main menu
  • +. Next page
  • -. Previous page
  • Make your choice:
  • Select 5: CLID string 1 and set to '00001'
  • CLID string 1: 00001
  • Press Enter key
  • Select +
  • Protocol options menu
  • 1. One account per call: Yes
  • 2. One event per block: Yes
  • 3. Three digit event numbers: No
  • 4. Text in SIA: Yes
  • 5. PA auto-restore: No
  • 6. Dual reporting: No
  • 7. Auto dial: No
  • 8. PC calls: Yes
  • 9. Protocol: V24
  • 0. Back to main menu
  • +. Next page
  • -. Previous page
  • Make your choice: Select 2: One event per block
  • One event per block (Y/N):Select Y
  • Do the same for 4: Select 'Y' for Text in SIA
  • Do the same for 8: Select 'Y' for PC calls
  • Select +
  • Protocol options menu
  • 1. Wait for modem reply : 005
  • 2. Wait for modem dial reply : 010
  • 3. Wait for redial : 015
  • 4. Max dial attempts/CS : 240
  • 5. Max modem command attempts: 003
  • 6. Event delay : 020
  • 7. DCD timeout : 255
  • 0. Back to main menu
  • +. Next page
  • -. Previous page
  • Make your choice: Do the same for 7
  • Set value to 255 for DCD timeout. This disables DCD timeout
  • Select 0 to go back to main menu:
  • Select 1: Central Station menu
  • Central station menu

  • 1. Central station 1
  • 2. Central station 2
  • 3. Central station 3
  • 4. Central station 4
  • 0. Back to main menu
  • Make your choice: Select 1: Central station 1
  • Central station 1 menu
  • 1. Account code 1 : 1111101
  • 2. Account code 2 : 1111102
  • 3. Account code 3 : 1111103
  • 4. Account code 4 : 1111104
  • 5. Account code 5 : 1111105
  • 6. Account code 6 : 1111106
  • 7. Account code 7 : 1111107
  • 8. Account code 8 : 1111108

  • 9. Network address: 511100
  • 0. Back to Central Station menu
  • Make your choice: Select 9
  • Network address and make sure there are 6 or more digits. They can be any combination.
  • Select 0 until you are at the main menu
  • Select 0: Exit MPI programming and follow instructions
  • Turn PC-programming dip-switch 3 on to exit.
  • Goodbye
  • Last and crucial, make sure switch 5 on the MPI232 module is set to OFF. This turns off callback mode.