Panel Connection - Serial

Manufacturer DSC
Model PC 161/1832/1864
Version EuroOne
Panel Profile DSCRS232
Cable required? Yes (5-538)
Serial Connection Serial
Panel Bus Connection RS232
Technical Notes Please see below

Panel Programming

Webway SPT DSC
232 T Pin 1
RTN Pin 2
232 R Pin 4

Galaxy Panel Connections

Galaxy Panel Connections

SPT Connections

SPT Connections

Serial Connectivity PC1616 / PC1832 / PC1864 Configuration

  • Engineer login and set-up: Press *8
  • Keypad displays ‘Enter Your Installer Code’ > Press 5555
  • Keypad displays ‘Enter Section’ > Press 015
  • Keypad displays ‘Toggle Option’ followed by’ 8 ‘ (This may have some set to numbers. If 7 is displayed, press 7 to remove it from the display. This disables Telephone line monitoring).
  • Press # > Press 301
  • Keypad displays may display some numbers and letters followed by lots of F’s Replace with ‘DCAA’ followed by all F’s. This adds TLink to route calls to.
  • Press # > Press 302 and do the same as in 301 but fill all with F’s. This will clear all possible telephone numbers
  • Press 350 > Keypad displays ‘Enter Data’
  • Press 04 then a moment later 04 again. This sets up alarms to be reported in SIA.
  • Press 380 > Keypad displays ‘Toggle Option’ followed by 8 this may have some numbers set. If 1 is not displayed, press 1 to add it to the display. This enables the system communicator.
  • Press # > Press 381
  • Keypad displays ‘Toggle Option’ followed by 8 this may have some numbers set. If 3 is displayed, press 3 to remove it from the display. This disables Automatic SIA codes.
  • Press # > Press 382
  • Keypad displays ‘Toggle Option’ followed by 8 this may have some numbers set. If 5 are not displayed, press 5 to add it to the display. This enables TLink communications.
  • Press # > Press 401
  • Keypad displays ‘Toggle Option’ followed by 8 this may have some numbers set. If 1 is not displayed, press 1 to add it to the display. This enables UDL communications to the DLS application.
  • Press #

Remote Access Programming

  • Go to set up downloading۪
  • Select download by (WebWayOne)
  • Select poll timeout <10>
  • Select modem init timeout <060>
  • Select rings to answer <1>
  • Select comm. Tx timeout <030>
  • Select ARMPC telephone number (not required)
  • Select program PCs <1>
  • Select modem telephone number (not required)
  • Select signal alarms (No)
  • Select signal faults (No)
  • Select signal set/unset (No)
  • Select signal access code (No)
  • Select password (optional UDL password)
  • Select redials <03>

  • Select time out <00>
  • Select stop on success (No)
  • Select dial mode (retry same)
  • Exit engineering mode and save the configuration