Panel Connection - MCM

Manufacturer DSC
Model Modem Capture Connection
Version EuroOne
Minimum Panel Firmware Range V3.43+
MCM Plug on required? MCM version less or equal to V1.05 - Needs SPT version less or equal to V2.06
MCM version greater or equal to V1.06 - Needs SPT version greater or equal to V2.07
MCM or Serial Connection MCM
Panel Bus Connection None
Technical Notes Please see below

Cable Connection

SPT Panel
MCM plug-on module - Line a PSTN Line A
MCM plug-on module - Line b PSTN Line B

Images

SPT and MCM module

SPT and MCM module

SPT and MCM module

SPT and MCM module

Modem Capture Connectivity PC1616/ PC1832/PC1864 Configuration

  • Connect the WebWay PSTN panel interface A and to the A and B terminals of the DSC control panel. Connect the WebWay PWR + and - to the Aux + and Aux - of the DSC control panel.
  • *8 Then enter installers code
  • 1. Go to section 301: Enter telephone number <01234 567890> (any valid phone number is acceptable)
  • 2. Go to section 310: Enter account number
  • 3. Go to section 350: Enter communicator format to SIA <04>
  • 4. Go to section 380: Ensure option 1 is enabled to <1________>
  • 5. Go to section 381: Ensure options 5 & 6 are enabled - the rest clear <____56__>
  • 6. Go to section 382: All must be clear <_________>
  • 7. Go to section 401: Option 1 must be set - the rest clear<1________>
  • 8. Go to section 403: Enter DLS access code <______>
  • 9. Go to section 404: Enter DLS panel identification code <______>
  • 10. Go to section 406: Set number of rings to <002>
  • Select content 17-32 (recommend 21-25, 27-30, & 32)
  • Select redials <03>
  • Select time out <15>
  • Select test calls (No)

Remote Access Programming

  • Go to set up downloading۪
  • Select download by
  • Select security mode
  • 4. Select telecom line
  • Select number of rings <3>
  • Select modem speed
  • Select ARMPC telephone number <123456>
  • Select program PCs <1>
  • Select modem telephone number (not required)
  • Select signal alarms (No)
  • Select signal faults (No)
  • Select signal set/unset (No)
  • Select signal access code (No)
  • Select password (optional UDL password)
  • Select redials <03>

  • Select time out <00>
  • Select stop on success (No)
  • Select dial mode (retry same)
  • Exit engineering mode and save the configuration