Panel Connection - TTL

Manufacturer HKC
Model Secure Wave
Version 1070
Panel Firmware Range V3 (UK) & V4 (UK)
Cable required? HKC Serial Cable (05-5039)
MCM or Serial Connection Serial
Panel Profile HKCV3
Panel Bus Connection TTL
Technical Notes Reporting of SPT path states to the panel is not supported via the serial interface. [Please use the SPT Outputs]
Technical Notes ** UPDATE ** UK Panel Firmware V3.3.3 (UK only) - All tested and working fine on SIA & UDL via the Webway SPT's

Cable Connection

PANEL SPT COLOUR
Pin 2 R -TTL Yellow
Pin 3 TTL - T Black
Pin 4 RTN Green

HKC Panel Connection

HKC Panel Connection

SPT Connection

SPT Connection

Panel Programming

  • No major panel settings are required for the webway to integrate to the Panel and then communicate SIA alarms.
  • Please check the "Remote User Code"...
  • Select Engineer Mode
  • Select Comms Menu
  • Select Remote User Menu
  • Then select remote user code
  • RO1 Remote user will be displayed, set and verify this as 1234 or as required.
  • Notify WebWayOne of the new code, or set this using mark 5 - menu H mark 6 - menu k on the webway communicator.

Troubleshooting

  • Reporting of SPT path states to the panel is not supported via the serial interface.
  • HKC - Error Message on UDL, Call Tech Support 01635 231514 so we change a background setting....
  • Should your installation require an indication of 'Path States' or Line Fault, you will need to wire up and use Output 1 and Output 2 to identify the alarm panel of a Alarm Transmission Path (ATP) failure.
  • Output 1 – Primary Path
  • Output 2 – Secondary Path
  • ** UPDATE ** Panel Firmware V3.3.3 - All tested and working fine on SIA & UDL via the Webway SPT's