Manufacturer InnerRange
Model Inception
Version Tested V0.0.0.2695.R0
Minimum SPT Version Nano & Pro V2.02
Cable Required Yes - InnerRange Product Code 9930360USB
MCM, Serial or Peripheral Serial
Panel Bus Connection TTL
Panel Type INNERANGE-INCEPTION-TTL
Technical Notes USB cable will require the White connector plug removing

Cable Connection

PANEL WebWay SPT Terminal
RTN - Black
USB R TTL - White
T TTL - Green

Panel Connection

Panel Connection

WebWay SPT Connection

WebWay SPT Connection

Inner range Inception Panel Set-up

  • The panel is only configurable using the Web Interface. Therefore an Ethernet cable must be plugged in the panel, and the engineer on site must have a laptop.

  • On the supplied USB stick, run ‘Inception Discovery tool’ to find the panel on the network.
  • Log in to the panel as installer. The default information is in the panel documentation.

  • Navigate to: Configuration > General > Alarm Reporting
  • Within the alarm reporting menu, select ‘WebWayOne Configuration’
  • This will drop down a list of options for WebWay Configuration
  • Tick ‘Enable WebWayOne Reporting’
  • Select your reporting type. Possible options are SIA and Contact ID.
  • Click save at the top of the screen.

  • It is possible to send through a batch of alarms to test, by clicking the ‘Send All Possible Alarms’ button.