Panel Connection - Serial

Manufacturer DSC
Model Maxsys
Version 4020
Panel Firmware Range v3:5
Cable required? yes 05-5038
Serial Connection Serial
Panel Profile DSCRS232
Panel Bus Connection RS232
Technical Notes Please see below

Serial Connection

WebWay SPT DSC
232 T Pin 1
RTN Pin 2
232 R Pin 4

Galaxy Panel Connections

Galaxy Panel Connections

SPT Connections

SPT Connections

Panel Programming Steps

  • 1) Engineer login and set-up: 1. Press *8
  • 2) Keypad displays ‘Enter Your Installer Code’
  • 3) Press 5555
  • 4) Scroll to (00) System Area and press *
  • 5) Scroll to (03) DLS Section and press *
  • 6) Scroll to (00) DLS Toggles and press *
  • 7) Set DLS Enabled = Y
  • 8) Press # twice
  • 9) Scroll to (04) Communicator and press *
  • 10) Scroll to (00) Main Items and press *
  • 11) Scroll to (00) 1st Number and press *
  • 12) Scroll to (00) Pgm Tel Number and press *
  • 13) Set to CAAA and remove ‘D’ from the beginning
  • 14) Scroll to (01) Comms Format and press *
  • 15) Set to SIA Fsk Format
  • 16) Scroll to (02) Dialer Direction and press *
  • 17) Toggle events to be sent.
  • 18) Press # twice.
  • 19) Scroll to (03) System Account and press *
  • 20) Set Account Code, normally same Site ID as SPT
  • 21) Press # until you are back to step 9) and clear 2nd and 3rd telephone number, then step 22)
  • 22) Scroll to (01) Communications options (CommsToggles) and press *
  • 23) Set Communicator Enabled = Y
  • 24) Set TLM Enabled = N
  • 25) Set Automatic SIA codes (AutoReport SIA) = Y
  • 26) Set TLink Enabled = Y

Remote Access Programming

  • Go to set up downloading۪
  • Select download by (WebWayOne)
  • Select poll timeout <10>
  • Select modem init timeout <060>
  • Select rings to answer <1>
  • Select comm. Tx timeout <030>
  • Select ARMPC telephone number (not required)
  • Select program PCs <1>
  • Select modem telephone number (not required)
  • Select signal alarms (No)
  • Select signal faults (No)
  • Select signal set/unset (No)
  • Select signal access code (No)
  • Select password (optional UDL password)
  • Select redials <03>

  • Select time out <00>
  • Select stop on success (No)
  • Select dial mode (retry same)
  • Exit engineering mode and save the configuration