WebWayWorld Logo 2018

 

Panel Connection - MCM

Manufacturer DSC
Model Maxsys 4020
Version 4020
Panel Firmware Range V3:5
MCM Plug on required? MCM version less or equal to V1.05 - Needs SPT version less or equal to V2.06
MCM version greater or equal to V1.06 - Needs SPT version greater or equal to V2.07
MCM MCM
Panel Profile DSC
Panel Bus Connection None
Technical Notes Please see below

Cable Connection

SPT Panel
MCM plug-on module - Line a PSTN Line A
MCM plug-on module - Line b PSTN Line B

Images

SPT and MCM module

SPT and MCM module

SPT and MCM module

SPT and MCM module

Panel Programming

  • Engineer login and set-up: 1. Press *8
  • Keypad displays ‘Enter Your Installer Code’ > Press 5555
  • Scroll to (00) System Area and press *
  • Scroll to (03) DLS Section and press *
  • Scroll to (00) DLS Toggles and press *
  • Set DLS Enabled = Y > Press # twice
  • Scroll to (04) Communicator and press *
  • Scroll to (00) Main Items and press *
  • Scroll to (00) 1st Number and press *
  • Scroll to (00) Pgm Tel Number and press *
  • Set to 01234 567890

  • Scroll to (01) Comms Format and press * > Set to SIA Fsk Format
  • Scroll to (02) Dialer Direction and press *
  • Toggle events to be sent > Press # twice.
  • Scroll to (03) System Account and press *
  • Set Account Code, normally same Site ID as SPT
  • Press # until you are back to step 9

  • Scroll to (01) Communications options and press *
  • Set Communicator Enabled = Y
  • Set TLM Enabled = N
  • Set Automatic SIA codes = Y
  • Set TLink Enabled = N

Remote Access Programming

  • Go to set up downloading۪
  • Select download by
  • Select security mode
  • 4. Select telecom line
  • Select number of rings <3>
  • Select modem speed
  • Select ARMPC telephone number <123456>
  • Select program PCs <1>
  • Select modem telephone number (not required)
  • Select signal alarms (No)
  • Select signal faults (No)
  • Select signal set/unset (No)
  • Select signal access code (No)
  • Select password (optional UDL password)
  • Select redials <03>

  • Select time out <00>
  • Select stop on success (No)
  • Select dial mode (retry same)
  • Exit engineering mode and save the configuration
  • Go to Site Options
  • Select ATE inputs

UDL information for this item can be found here: