WebWayWorld Logo 2018

 

Panel Connection - Serial

Manufacturer Menvier
Model Menvier
Version M-Series
Panel Firmware Range MIN V1:01
Cable required? Yes 05-5017
MCM or Serial Connection Serial
Panel Profile M1000
Panel Bus Connection RS232
Technical Notes Panels supported on M-Series: M1000 & M2000

Cable Connection

Panel SPT Colour
9 Way D-Type Pin 2 232 T Blue Wire
9 Way D-Type Pin 3 232 R Red Wire
9 Way D-Type Pin 5 RTN Yellow Wire

Galaxy Panel Connections

Galaxy Panel Connections

SPT Connections

SPT Connections

Panel Configuration

  • The M Series main board assembly has a 9 way D-type connector at the top right. This connects to the T, R terminals of the WebWayOne panel interface.

  • The physical connection details at the WebWay are as follows:
  • Blue cable to T
  • Red cable to R
  • Yellow cable to RTN

  • Go to Engineer Level 2
  • Option 5 Communications
  •      Option 2 Digicom
  •         Option 1 Comms Format
  •             Set to Option 7 - Extended SIA level 3
  •         Option 2 ARC No 1
  •             Set telephone number to <01666111>
  •     Back to Digicoms option 2
  •         Option 3 for account numbers
  •             Enter the Account Number 1 <_______>
  •     Option 4 Dialling mode Should be set to - Consecutive -
  •     Option 5, Options
  •         Option 1 Restore signals select
  •         Option 2 Fast Format <8FF Channels>
  •     Back to Digicoms Option 2
  •         Option 6 CID/SIA reports set to [Full]

  • Back to Engineer Level 2
  •     Option 5 Communications
  •         In Option 4 RS232 options
  •             Ensure Option 1 - Select RS232 baud <38400>
  •             And Option 2 - Select Remote Modem

  • Back to Go to Engineer Level 2
  •     Option 5 Communications
  •         Select Option 1 downloader
  •             Enter Option 1 and Select Password <______>
    (same as configured in downloader application)
  •             Enter Option 2 Select site ID <______> 
    (same as configured in downloader application)

  • Communications Option 5
  •     Select Option 1 - Downloader
  •     Set Option 3, Select access mode to - Unattended -
  •     Set Option 4, Edit call No 1 to - BLANK -
  •     Option 5 Modem Options ensure
  •         Option 1 - Select rings to answer Option 1 is - Immediate -
  •         Option 2 - Select baud rate - 1200 - (2400 if available)
  • Finally exit Engineering/Full downpower of WebWay & Panel to establish electrical connection.

Remote Access Programming

  • Go to ‘set up downloading’
  • Select download by (WebWayOne)
  • Select poll timeout <10>
  • Select modem init timeout <060>
  • Select rings to answer <1>
  • Select comm. Tx timeout <030>
  • Select ARMPC telephone number (not required)
  • Select program PCs <1>
  • Select modem telephone number (not required)
  • Select signal alarms (No)
  • Select signal faults (No)
  • Select signal set/unset (No)
  • Select signal access code (No)
  • Select password (optional UDL password)
  • Select redials <03>

  • Select time out <00>
  • Select stop on success (No)
  • Select dial mode (retry same)
  • Exit engineering mode and save the configuration

UDL information for this item can be found here:

Support

Knowledge Base

Panel Guides

Downloads

FAQs