Panel Connection

Manufacturer Orisec
Model CP-10CP-20CP-25CP-30W-CP-40CP-50CP-100CP-200
Minimum Panel firmware CP-10 V1.00CP-20 V1.00CP-25V1.10CP-30 V3.10W-CP-40 V1.42CP-50 V1.84CP-100 V1.84CP-200 V1.84
Cable Required Yes - Orisec & Galaxy cable (05-0222)
WebWay SPT Min Firmware Nano & Pro V2.01
MCM, Serial or Peripheral Serial
Panel Profile ORISEC CP TTL
Panel Bus Connection TTL
Technical Notes WebWay Firmware V2.03 is incompatible with Orisec Panels, Please downgrade to V2.02

Cable Connection

PANEL (COM1) SPT
Green (Pin2) RTN
Red (Pin3) R - TTL
Brown (Pin4) T - TTL

Pro Unit Connection

Pro Unit Connection

  • On the Orisec control panel the following willl need to be programmed to integrate to transmit events.

  • Enter engineering mode on the panel using the Engineer code, followed by the Manager code.

  • Programming Menu
  • Navigate to ARC-Setup Menu 17
  • Insert or Modify the following
  • Account = ARC Account ID
  • Protocol = SIA3 or Contract ID
  • Dial Seq = 2
  • Reported = Set triggers as required
  • Area = Set areas as required
  • IP Address = Clear value
  • IP Port = Clear value
  • Exit back to Programming Menu
  • Select Com Port Setup Menu 13
  • Insert or Modify the following
  • Com port = 1
  • Mode = WebWayOne SPT/Unit
  • Exit Engineering

Technical Notes

  • Line fault is through the serial interface, no extra settings are required in either the panel or SPT

UDL information for this item can be found here:

UDL Requirements - Remote Manager V3.4.0.1 & Orisec UDL V3.0.0.4