WebWayWorld Logo 2018

 

Panel Connection - Serial

Manufacturer Pyronix
Model Euro
Version 280
Minimum Panel Firmware Range V9.54d
WebWayOne Cable required? No - Standard 3 wire cable can be used
MCM or Serial Connection Serial
Panel Profile Castle
Panel Bus Connection RS232
Support Information Please see end of page

Cable Connection

SPT Panel
RS232 T FPRS232 Module - RXD
RS232 R FPRS232 Module - TXD
RTN FPRS232 Module - GND

Images

SPT

SPT

Panel's FPRS232 Module

Panel's FPRS232 Module

Panel Programming

  • Login to panel's Engineer mode
  • Go to and select PROGRAM ARC/SMS? and then Calls?
  • Set ARC/SMS to Enabled’ [0]
  • Select ARC Details [1] and set Active to Yes [1]
  • Set Format to WebWayOne [141]
  • Set SIA Ack Char [006]
  • Set SIA Nack Char [021]
  • Valid Areas is Engineer’s choice
  • Area Accounts is Engineer’s choice
  • Set ARC Account to Site ID/Account No
  • Set Content [1-32] Engineer’s choice
  • Set Redials [03]
  • Set Time Out Seconds [30]
  • Set Test Calls is Engineer's choice
  • Exit Engineer Mode into Day Mode

Remote Access Programming

  • Go to ‘Set Up Downloading’
  • Select Download by (WebWayOne) [4]
  • Select Poll Timeout [10]
  • Select Modem Init Tmout [060]
  • Select Rings To Answer [1]
  • Select Comm Tx Timeout [030]
  • Select Comm Dial Tmout [030]
  • Select UDL Tx Timeout [02]
  • Select ARMPC Tel No, enter 1111
  • Select Program PCs [1]
  • Modem Tel No, enter 1111
  • Select Signal Alarms No [0]
  • Select Signal Faults No [0]
  • Select Signal Set/Unset No [0]
  • Select Signal Access C. No [0]
  • Select UDL Password (Optional)
  • Exit engineering mode and save the configuration

Limitations

  • Panel ARM feature is not supported. Waiting for panel support in Pyronix Insite application.