WebWayWorld Logo 2018

 

Panel Connection - Serial

Manufacturer Pyronix
Model Euro
Version 46
Minimum Panel Firmware Range V10
WebWayOne Cable required? Yes 05-5031
MCM or Serial Connection Serial
Panel Profile Castle
Panel Bus Connection RS232
Support Information Please see end of page

Cable Connection

SPT Cable
RS232 T BLUE
RS232 R RED
RTN GREEN

Images

SPT Pro Connections

SPT Pro Connections

Panel Connections

Panel Connections

Panel Programming

  • Login to panel's Engineer mode
  • Go to and select COMMUNICATIONS? and then PROGRAM ARC/SMS?
  • Select ARC DEATILS?
  • Set Format to WebWayOne [141]
  • Set SIA Ack Char [006]
  • Set SIA Nack Char [021]
  • Valid Areas is Engineer’s choice
  • Area Accounts is Engineer’s choice
  • Set ARC Account to Site ID/Account No
  • Set Redials [003]
  • Set Time Out [30]
  • Test Calls is Engineer's choice
  • Event Types is Engineer's choice

Remote Access Programming

  • Go to ‘Set Up Downloading’
  • Set Download by (WebWayOne) [4]
  • Set Poll Timeout [10]
  • Set Modem Init Tmout [060]
  • Set Rings To Answer [1]
  • Set Comm Tx Timeout [030]
  • Set Comm Dial Tmout [030]
  • Set UDL Tx Timeout [02]
  • Set Redials [03]
  • Set Roving Dial to No [0]
  • Set Auto Upload to No [0]
  • UDL Password is Engineer's choice
  • Site Name is Engineer's choice
  • Go into Communications Menu and hit "NO "until Advanced Communications
  • Yes to enter, Press Yes until ARM PC Tel NO.
  • Enter 1111
  • Press YES until Program PC 1
  • If the Modem Tel No or similar is in the list, enter 1111

Limitations

  • Panel ARM feature is not supported by the panel. Believed to be a panel feature fault.

UDL information for this item can be found here: