Panel Connection - MCM (Alarms) & Serial (UDL)

Manufacturer Risco
Model Agility
Panel Firmware Range v2.33
Cable required? Risco Lightsys & Agility Cable (05-5040)
MCM Plug on required? MCM version less or equal to V1.05 - Needs SPT version less or equal to V2.06
MCM version greater or equal to V1.06 - Needs SPT version greater or equal to V2.07
MCM or Serial Connection MCM
Panel Profile RISCO AGILITY MCM AND SERIAL
Panel Bus Connection RS232
SPT Firmware V2.16 or greater
Technical Notes SPT will require additional enclosure - due to no space in @inside' the panel for the SPT

Cable Connection

PANEL SPT CABLE COLOURS
Serial Pin 1
Serial Pin 2 (Centre)
Serial Pin 3
232 -T
RTN
R-232
Red
Blue
Yellow
Terminal A
Terminal B
Terminal a
Terminal b
Red
Black

Agility Panel Serial Connection

Agility Panel Serial Connection

Agility Panel MCM Connection

Agility Panel MCM Connection

SPT PRO. MCM and Serial Connections

SPT PRO. MCM and Serial Connections

Risco Panel Keypad Discription

Risco Panel Keypad Discription

Panel Programming

  • Login to Engineer Mode [*] and enter Engineer Code
  • Scroll to [1) System] and press [#] (or OK)
  • Scroll ↓ to [2) Controls] and press [#]
  • Scroll ↓↓ to [3) Communication] and press [#]
  • Scroll ↓↓ to [ARC ENABLE] and set to 'Y' and press [#]
  • Screen shows [3) Communication] and press [#]
  • Scroll ↓ to [Config SW Enable] and set to 'Y' and press [#]
  • Press [*] 2 twice you are now in the Main Menu
  • Scroll ↓↓↓ to [4) Communications] and press [#]
  • Scroll ↓ to [2) ARC] and press [#]
  • Screen shows [1) Report Type] and press [#]
  • Screen shows [ARC 1] and press [#]
  • Screen shows [Select channel] and scroll to [Voice] press [#]
  • Screen shows [Select priority] and scroll to [PSTN Only] press [#]
  • Screen shows [Enter Phone] and input [012345678] press [#]
  • Remove any entries in [ARC 2] and [ARC 3]
  • Scroll ↓ to [2)Accounts] and press [#]
  • Screen shows [1) ARC 1] and press [#] and enter account number and press [#]
  • Remove any entries in [ARC 2] and [ARC 3] and Press [*]
  • Scroll ↓ to [3) Comm Format] and press [#]
  • Scroll down to [SIA] and press [#]
  • Scroll down to [4) Controls] and press [#]
  • Set [Handshake] to [Y] and scroll down and set [Kiss-Off] to [Y] and press [#]
  • Press [*]
  • Scroll ↓ to [3) Config. SW] and press [#]
  • Screen shows [1) Security] and press [#]
  • Scroll ↓ to [2) Remote ID] and press [#]
  • Modify value to [0000] and press [#]
  • Screen shows [2) Remote ID] Press [*] Press ↓
  • Screen shows [2) Call Back] Press [#] and set [Call Back En] to [N] and press [#]
  • Press [*]
  • Scroll ↓ [3) IP Gateway] Press [#] into [1) IP Address] Remove any IP Config.
  • Scroll ↓ [2)IP Port] Press [#] Modify value to [00000] and press [#]
  • *** If you have a GSM modules Remove Setting from this Menu ***
  • Press [*] 3 times
  • Screen shows [4) Communication]
  • Now Exit Engineer Mode [0] and Press [#] this saves the data

Trouble shooting

  • NOTE : Risco Agility has two Communication Menu’s, please check you are in the correct Communication Menu during panel programming