WebWayWorld Logo 2018

 

Panel Connection - MCM

Manufacturer Risco
Model GardTec GT600
Version GT600/GT601
Panel Firmware Range N/A
MCM Plug on required? MCM version less or equal to V1.05 - Needs SPT version less or equal to V2.06
MCM version greater or equal to V1.06 - Needs SPT version greater or equal to V2.07
MCM or Serial Connection MCM
Panel Profile GARDTECDIGI
Panel Bus Connection None
Technical Notes Please see below

SPT Fitting

WebWay Modem Cpature Gardtec
A A5 IN
B B2 IN
RTN RTN

Galaxy Panel Connections

Galaxy Panel Connections

SPT Connections

SPT Connections

Panel Programming

  • Digicom SIA and Triggers:
  • 1. Press [1][2][3][4][YES] to get into Engineer mode (If prompted also enter the authorise code)
  • 2. If prompted ‘Do you want to use engineer mode - enter [Yes]
  • 3. Press [3][4][YES] to jump to Digicom
  • 4. Press [NO] until you see ‘Mod + SIA’
  • 5. Press [YES]
  • 6. Press [0]
  • 7. Press [NO] until you see ‘Channels’
  • 8. Press [YES][YES] (To change channels/triggers)
  • 9. Press [NO] once
  • 10. Press [YES] until the “>” appears next to PA
  • 11. Press [NO] to change the ‘Off’ to ‘On’
  • 12. Press [YES][YES]
  • 13. Press [0] repeatedly to get out of Engineer mode

  • Digicom switching ON and Entering phone number:
  • 1. Press [1][2][3][4][YES] to get into Engineer mode
  • 2. Press [3][4][YES] to jump to Digicom
  • 3. Press [0] (go back)
  • 4. Press [NO] until you see ‘Functions’
  • 5. Press [YES]
  • 6. Press [NO] until you see ‘Comms Functions’
  • 7. Press [YES]
  • 8. Press [NO] until you see ‘Comms=On’
  • 9. Press [YES]
  • 10. Press [NO] and key in the required Site Code/Id
  • 11. Press [YES]
  • 12. Press [NO] and key in the required ARC telephone number
  • 13. Press [YES]
  • 14. Press [0] repeatedly to get out of Engineer mode

  • Set Line Monitor to low security:
  • 1. Press [1][2][3][4][YES] to get in to engineer mode.
  • 2. Press [3][4][YES] to jump to Digicom
  • 3. Press [0] (go back one menu place)
  • 4. Press [NO] till you see 'Functions'
  • 5. Press [YES]
  • 6. Press [NO] till you see 'Comms Functions'
  • 7. Press [YES]
  • 8. Press [YES] till you see 'Line Monitor'
  • 9. Press [NO] till you see 'Line Volts'
  • 10. Press [YES]
  • 11. Press [[NO] till you see 'Line Security'
  • 12. Press [NO] until ‘Low’
  • 13. Press [YES
  • 14. Press [0] multiple times to get out of engineer mode

Set modem for UDL connectivity:

  • Press [1][2][3][4][YES] to get in to engineer mode.
  • Press [3][4][YES] to jump to Digicom
  • Press [0] (go back one menu place)
  • Press [NO] till you see 'Functions'
  • Press [YES]
  • Press [NO] till you see 'Program Modem Functions'
  • Press [YES]
  • Press [NO] till you see ‘Modem Mode’
  • Press [NO] till ‘No Return’ is selected.
  • Press [YES].
  • Next you will see ‘Double Ring’
  • Press [NO] until ‘Off’ is selected.
  • Press [YES] until ‘Site ID code’
  • Press [NO] and insert Site\account number
  • Press [YES] and you will see ‘Password’

  • Press [NO] and insert password
  • Press [YES] and you will see ‘Phone number 1’
  • Press [NO] and insert any telephone number
  • Press [YES] until you see ‘Modem Access’
  • Press [NO] until ‘Any Time’ is selecte
  • Press [YES]
  • Press [0] multiple times to get out of engineer mode