Panel Connection - RS232

Manufacturer Risco
Model Lightsys
Version Lightsys, Lightsys II
Panel Firmware Range v1.62
Cable required? Risco Lightsys & Agility Cable (05-5040)
DCM or Serial Connection Serial
Panel Profile RISCO LITESYS RS232 SERIAL
Panel Bus Connection RS232
Technical Notes See troubleshooting below

Cable Connection

Panel SPT Colour
Pin 1 T Red
Pin 2 RTN BLUE
Pin 3 R Yellow

Panel Connection

Panel Connection

SPT Connection

SPT Connection

Panel Programming

  • Login to Engineer Mode - Exit /Menu Button + Engineer Code + OK
  • Keypad shows 1] Programming and press OK
  • Scroll to 1] System and press OK
  • Scroll ↓ to 2] Controls and press OK
  • Scroll ↓↓ to 3] Communication and press OK
  • Scroll ↓↓ to ARC ENABLE and set to 'N' and press OK
  • Screen shows 3] Communication and press OK
  • Scroll ↓ to FM Enable and set to 'N' and press OK
  • Screen shows 3] Communication and press OK
  • Scroll ↓↓ to CS ENABLE and set to 'Y' and press OK
  • Press Exit / Menu Button 2 twice you are now in the Main Menu
  • Scroll ↓↓↓ to 5] Communications and press OK
  • Scroll ↓ to 3] Config. SW and press OK
  • Screen shows 1] Security and press OK
  • Scroll ↓ to 2] Remote ID and press OK
  • Modify value to 00000 and press OK
  • Screen shows 2] Remote ID Press Exit / Menu Button Press ↓
  • Screen shows 2] Call Back. Press OK and ensure NO PHONE NUMBERS are set
  • Press Exit / Menu Button x4 times
  • Screen shows 5] Communication.
  • Now Exit / Engineer Mode 0 and Press OK this saves the data

Trouble shooting

  • NOTE: Risco Lightsys has two Communication Menu’s, please check you are in the correct Communication Menu during panel programming.
  • Ensure upon initail panel start up that the Language selection is Used otherwise Arc Enable will not show under Communications Menu 3.
  • To amend this go to [Programming][System][Settings][Customer] and change it from ‘0EN’ to ‘0UK’ (as it should be for us in the UK)
  • By doing this, they will forfeit the entire programming as the panel will invoke a full default for ‘UK’ settings.
  • NOTE: Litesys panel integration does not support non zone type alarms such as BV (Burglary Verified).