Panel Connection - Serial

Manufacturer Cooper Safety
Model Scantronic / Menvier
Version ION (100, 160, 300, 1000)
Panel Firmware Range MIN - V4:03
Cable required? Yes - Any Standard Alarm Cable
Serial Connection Serial
Panel Profile ION
Panel Connection TTL
Technical Notes The Scantronic i-on requires a special serial connector from WebWayOne in order to allow full SIA and upload/download functionality. The serial connector is fitted as shown.

WebWay Cable Wiring: Please complete as follows with standard alarm cable.

WebWay SPT Serial Board
TTL - T R
TTL - R T
RTN RTN

WebWay ION Interface Adaptor situated on the panel.

WebWay ION Interface Adaptor situated on the panel.

SPT Connections

SPT Connections

Panel Programming

  • To configure the panel, the SPT must be fully configured and wired to the panel and then rebooted. This causes the panel to query all devices connected and make available various menu options available in the Keypad and in the Web browser
  • Panel Communication on initial setup
  • If no data transfer has occurred between the WebWay and the Scantronic i-on after a short period of time, the panel stops communicating and will require a restart to begin again. This only applies to the initial setup and does not affect ongoing alarm communications.
  • Enter Engineer mode
  • 1. INSTALLER MENU will be displayed with Detectors/Devices below.Press the down key until you find Communications Press the right key

  • 2. COMMUNICATIONS will be displayed with ARC Reporting below it. Press the right key
  • 3. ARC REPORTING will be displayed with Call Mode below it. Press the right key.
  • 4. CALL MODE will be displayed. Use the up and down keys to select Single. Press the Accept\Tick key.
  • 5. Press the down key.
  • 6. ARC REPORTING will be displayed with IP Network below it. Press the right key.
  • 7. IP NETWORK will be displayed with Unit Name below it. Press the right key. Then enter a description name** and press the Accept\Tick key.
  • 8. Press the down key.
  • 9. POLLING IP Address will be displayed, press right key and clear the contents. Press the Accept\Tick key.
  • 10. Press the down key.
  • 11. ARC IP Address will be displayed, press right key and IP Address 1 is displayed
  • 12. Enter the IP address 127.0.0.1 (for dot press * key).Press the Accept\Tick key.
  • 13. Change IP ADDRESS 1 to the description name as chosen in step 7. Press the Accept\Tick key.
  • 14. Press the down key and IP Address 2 is displayed. Press right key and clear contents.
  • 15. Press the Accept\Tick key twice.
  • 16. Press the left key twice back to ARC REPORTING will be displayed with IP Network below it.
  • 17. Press the down key and Account Numbers will be displayed.
  • 18. Press right key and select Accounts to enter account numbers.
  • 19. Back to ARC REPORTING and Account Numbers.
  • 20. Report Type will be displayed, press theright key, then select SC SIA 3
  • 21. CID/SIA Events, press the right key, then set selection.
  • 22. Restorals, press the right key, then set selection

  • 23. Back to COMMUNICATIONS.
  • 24. IP Network (Own) press the right key, then on Module: Ethernet, press the right key. Enter the following IP Address = 127.0.0.1
  • 25. IP Network (Own) > Module: Ethernet > Port Number = 55132
  • 26. IP Network (Own) > Module: Ethernet > Subnet Mask = 255.255.255.0
  • 27. IP Network (Own) > Module: Ethernet > Gateway Address = 127.0.0.1
  • 28. Downloading > Account > Name = As per Installation
  • 29. Downloading > Account > Serial Number = Any 8 digit number, this must match the numbered entered into the UDL software.
  • 30. Downloading > Access Mode = Unattended
  • 31. Downloading > P Network > IP Address > IP Address 1 = 127.0.0.1
  • 32. Downloading > IP Network > IP Address > IP Address 1 change to description chosen earlier
  • 33. Downloading > IP Network > IP Address > IP Address 2 = empty
  • 34. Downloading > IP Network > Port Number > select the descriptor chosen earlier = 55132
  • 35. Downloading > IP Network > Port Number > IP Address 2 = empty

For panel version 4.0 firmware and above

  • Login to panel as a user
  • Select System Config > Facilities On/Off > set Remote Access to ON
  • Select poll timeout <10>
  • Select modem init timeout <060>
  • Select rings to answer <1>
  • Select comm. Tx timeout <030>
  • Select ARMPC telephone number (not required)
  • Select program PCs <1>
  • Select modem telephone number (not required)
  • Select signal alarms (No)
  • Select signal faults (No)
  • Select signal set/unset (No)
  • Select signal access code (No)
  • Select password (optional UDL password)
  • Select redials <03>

Web Access – Only complete these steps if web access is needed

  • If you require Web Access then the panel requires a fixed IP address allocated to it.
  • IP Network (Own) > Panel Ethernet > Web Server > Status = Enabled
  • IP Network (Own) > Panel Ethernet > Web Server > Port Number = 80
  • Exit engineering mode and save the configuration
  • IP Network (Own) > Panel Ethernet > IP Address = allocated IP address
  • IP Network (Own) > Panel Ethernet > Subnet Mask = 255.255.255.0
  • IP Network (Own) > Panel Ethernet > Gateway Address = allocated IP addres
  • Known Panel Issue - Some panels require a timer to be adjusted to the background of the UDL Package.

UDL information for this item can be found here: