WebWayWorld Logo 2018

 

Panel Connection - MCM

Manufacturer Cooper Safety
Model Scantronic
Version 8136
Panel Firmware Range V5:1
MCM Plug on required? MCM version less or equal to V1.05 - Needs SPT version less or equal to V2.06
MCM version greater or equal to V1.06 - Needs SPT version greater or equal to V2.07
MCM or Serial Connection MCM
Panel Profile SCANTRONIC8136
Panel Bus Connection None
Technical Notes Please see below

Cable Connection

SPT Panel
MCM plug-on module - Line a PSTN Lina A
MCM plug-on module - Line b PSTN Line B

Images

SPT and MCM module

SPT and MCM module

SPT and MCM module

SPT and MCM module

Panel Programming

  • Panel Login
  • 1. (Menu>)= X key
  • 2. (Enter) = Tick key
  • 3. Default Keypad User code = 1234 (Menu)
  • 4. [0 Installer Programming] will be displayed, press (Enter)
  • 5. [00 Program System] will be displayed, input 71

  • 6. [71 Communication options] will be displayed, press (Enter)
  • 7. [Dial Type] will be displayed, set to ‘DTMF’ and press (Enter)
  • 8. [Call Mode] will be displayed, set to ‘Single’ and press (Enter)
  • 9. [3 Way Call] will be displayed, set to ‘Disabled’ and press (Enter)
  • 10. [Dynamic Test] will be displayed, set to ‘Disabled’ and press (Enter)
  • 11. [Static Test] will be displayed, set to ‘Disabled’ and press (Enter)
  • 12. [Line Integrity] will be displayed, set to ‘Disabled’ and press (Enter)
  • 13. [Line Monitor] will be displayed, set to ‘Enabled’ and press (Enter)
  • 14. [Report Restorals] will be displayed, set to ‘Enabled’ and press (Enter)
  • 15. [Log with Partns] will be displayed, set to ‘Enabled’ and press (Enter)
  • 16. [Format] will be displayed, set to ‘Extended SIA 3’ and press (Enter)
  • 17. [SIA Tone Format] will be displayed, set to ‘Bell 103’ and press (Enter)
  • 18. [Report Mode] will be displayed, set to ‘Full’ and press (Enter)
  • 19. [TA->BA] will be displayed, set to ‘Enabled’ and press (Enter)
  • 20. [Acknowledge] will be displayed, set to ‘Tonal’ and press (Enter)

  • 21. [71 Communication options] will be displayed, input 72
  • 22. [72 Program Phone Numbers] will be displayed, press (Enter)
  • 23. [T01:Number=] will be displayed, press (Enter)
  • 24. Input a random telephone number, press (Enter)
  • 25. Note: number must NOT be ‘123456’
  • 26. [T01:Account No] will be displayed, press (Enter)
  • 27. Input account or site id, press (Enter) twice
  • Panel Setting for UDL:

  • The panels call-back feature requires enabling for successful UDL communications.
  • After engineer login.

  • [0 Installer Programming] will be displayed, press (Enter)
  • [00 Program System] will be displayed, input 73
  • [73 Downloader Options] will be displayed, press (Enter)
  • [Account Name] will be displayed
  • Input account name, press (Enter). Note: The account name must match what is stored in the UDL application
  • [Rings to Answer] will be displayed, Input 1, press (Enter)
  • [Answer on 1 Ring] will be displayed, set to ‘Disabled’, press (Enter)
  • [Secure Callback] will be displayed, set to ‘Enabled’, press (Enter)
  • [T01:Download No] will be displayed, press (Enter)
  • Input ‘123456’, press and then press (Menu)

Remote Access Programming

  • Go to ‘set up downloading’
  • Select download by (WebWayOne)
  • Select poll timeout <10>
  • Select modem init timeout <060>
  • Select rings to answer <1>
  • Select comm. Tx timeout <030>
  • Select ARMPC telephone number (not required)
  • Select program PCs <1>
  • Select modem telephone number (not required)
  • Select signal alarms (No)
  • Select signal faults (No)
  • Select signal set/unset (No)
  • Select signal access code (No)
  • Select password (optional UDL password)
  • Select redials <03>

  • Select time out <00>
  • Select stop on success (No)
  • Select dial mode (retry same)
  • Exit engineering mode and save the configuration

UDL information for this item can be found here:

Support

Knowledge Base

Panel Guides

Downloads

FAQs