Panel Connection - MCM

Manufacturer Eaton
Model Scantronic
Series 9X5X Series
Panel Profile Scantronic 9x5x
MCM Plug on required? MCM version less or equal to V1.05 - Needs SPT version less or equal to V2.06
MCM version greater or equal to V1.06 - Needs SPT version greater or equal to V2.07
MCM or Serial Connection to Panel MCM
Panel Bus Connection None
Technical Notes Input 51 to submit Date/Time Changes

Cable Connection

SPT Panel
MCM plug-on module - Line a PSTN Line A
MCM plug-on module - Line b PSTN Line B

Images

SPT and MCM module

SPT and MCM module

SPT and MCM module

SPT and MCM module

Panel Programming

  • [Installer Mode] will be displayed
  • Input 101, press (Enter)
  • [101:Comms] will be displayed, press 1 (Single) & (Enter)
  • Input 103, press (Enter)
  • [103:Format] will be displayed, press 5 (Extended SIA 3) & (Enter)
  • Input 112, press (Enter)
  • [112:Rings To Ans] will be displayed, press 0 (Any) & (Enter)
  • Input 114, press (Enter)
  • [114:CallBack] will be displayed, press 2 (Any) & (Enter)
  • [115:Tel No 1] will be displayed, press (Enter) and input telephone number<01234 567890> & (Enter)
  • Input 117, press (Enter)
  • [117:AccountNo] will be displayed, press (Enter) and input account number and press (Enter)
  • Input 131, press (Enter)
  • [131:Mode] will be displayed, press 3 (Full) & (Enter)
  • Input 89, press (Enter)
  • [89:Confirm] will be displayed, press 0 (Off) & (Enter)
  • Select test calls (No)

  • Exit Engineer Mode into Day Mode

Remote Access Programming

  • Go to ‘set up downloading’
  • Select download by (WebWayOne)
  • Select poll timeout <10>
  • Select modem init timeout <060>
  • Select rings to answer <1>
  • Select comm. Tx timeout <030>
  • Select ARMPC telephone number (not required)
  • Select program PCs <1>
  • Select modem telephone number (not required)
  • Select signal alarms (No)
  • Select signal faults (No)
  • Select signal set/unset (No)
  • Select signal access code (No)
  • Select password (optional UDL password)
  • Select redials <03>

  • Select time out <00>
  • Select stop on success (No)
  • Select dial mode (retry same)
  • Exit engineering mode and save the configuration