Panel Connection - Serial

Manufacturer Eaton
Model Scantronic
Series S95
Panel Firmware Range V.1:06
Panel Profile Scantronics 95
DCM or Serial Connection Serial
Panel Bus Connection RS232
Cable required? Yes 05-0517
Technical Notes Please see below

Cable Connection

Panel SPT Colour
9 Way D-Type Pin 2 232 T Blue Wire
9 Way D-Type Pin 3 232 R Red Wire
9 Way D-Type Pin 5 RTN Yellow Wire

Galaxy Panel Connections

Galaxy Panel Connections

SPT Connections

SPT Connections

Panel Programming

  • Go to Menu 52 Digicom
  • Select Comms Format
  • Select ARC No <01234 567890>
  • Select account no <_____> (Ignore accounts 2-8)
  • Select dialing mode
  • Select DigiCom options
  • Select Restore signals
  • Select FF Channels <8 FF Channels>
  • Select Line fault

  • Go to Menu 53 – RS232 Options
  • Select RS232 option baud <38400>
  • Select Remote modem
  • Go to Menu 51
  • Select Serial Number <_____> (Site/Chip ID)
  • Select Account Name <_____> (Site/Chip ID)
  • Select Access mode
  • Select Edit call Nos
  • Select Modem Options rings to answer
  • Select Baud Rate <1200>
  • Select Downloader – Modem Options – Ans Phone Defeat

Remote Access Programming

  • Go to ‘set up downloading’
  • Select download by (WebWayOne)
  • Select poll timeout <10>
  • Select modem init timeout <060>
  • Select rings to answer <1>
  • Select comm. Tx timeout <030>
  • Select ARMPC telephone number (not required)
  • Select program PCs <1>
  • Select modem telephone number (not required)
  • Select signal alarms (No)
  • Select signal faults (No)
  • Select signal set/unset (No)
  • Select signal access code (No)
  • Select password (optional UDL password)
  • Select redials <03>

  • Select time out <00>
  • Select stop on success (No)
  • Select dial mode (retry same)
  • Exit engineering mode and save the configuration