Panel Connection - MCM

Manufacturer Siemens
Model SPC 4300
SPT Minimum Version Nano & Pro V1.14
Panel Firmware Range V2.1.0
MCM Plug on required? MCM version less or equal to V1.05 - Needs SPT version less or equal to V2.06
MCM version greater or equal to V1.06 - Needs SPT version greater or equal to V2.07
MCM or Serial Connection MCM
Panel Profile SIEMENSDIGI
Panel Bus Connection None
Technical Notes Please see below

SPT Fitting

WebWay Modem Cpature Siemens (PC137421 MCM Unit)
A A
B B

MCM Connections

MCM Connections

SPT and MCM Connections

SPT and MCM Connections

Panel Programming

  • Default Keypad Login code = 1111
  • 1) Login to panel
  • 2) [FULL ENGINEER] will be displayed.
  • 3) Press [SELECT] button. [SYSTEM STATUS] will be displayed.
  • 4) Scroll down menu until [COMMUNICATION] is displayed and press [SELECT].
  • 5) Scroll down menu until [MODEMS] is displayed and press [SELECT].
  • 6) [PRIMARY] is displayed. Press [SELECT].
  • 7) [ENABLE MODEM] is displayed. Press [SELECT] to set modem to be enabled.
  • 8) Scroll down menu until [COUNTRY CODE] is displayed and press [SELECT] to set to UK.
  • 9) Scroll down menu until [ANSWER MODE] is displayed and press [SELECT] to set to numbered rings of 1 ring.
  • 10) Scroll down menu until [LINE MONITORING] is displayed and press [SELECT] to set mode to disabled.
  • 11) Press the [BACK] button until [PRIMARY] is displayed.
  • 12) Scroll down menu until [BACKUP] is displayed and press [SELECT] to disable the backup modem.
  • 13) Press the [BACK] button until [MODEMS] is displayed.

  • 14) Scroll down menu until [CENTRAL STATION] is displayed and press [SELECT].
  • 15) [ADD] will be displayed. Press [SELECT] to create a new Central Station account.
  • 16) Input account ID and press the [ENTER] button. (Press and hold key for number input)
  • 17) Input account name and press the [ENTER] button.
  • 18) Select [SIA] as the protocol to use and press [SELECT].
  • 19) Input the 1st Phone number and press the [ENTER] button.
  • 20) Clear 2ndPhone number and press the [ENTER] button.
  • 21) Press the [BACK] button until [CENTRAL STATION] is displayed.
  • 22) Scroll down menu until [REMOTE MAINT.] is displayed and press [SELECT].
  • 23) Enable Remote Maintenance.

  • 24) Scroll down menu until [ID] is displayed and press [SELECT].
  • 25) Input ID.
  • 26) Scroll down menu until [PASSWORD] is displayed and press [SELECT].
  • 27) Input password.
  • 28) Scroll down menu until [IN CONN. SETTS.] is displayed and press [SELECT].
  • 29) Disable IP.
  • 30) Press back until [REMOTE MAINT] is displayed
  • 31) Scroll down menu until [SPC Pro] is displayed and press [SELECT].
  • 32) Enable access, input ID and passwords.
  • 33) Disable IP.
  • 34) Press [BACK] until no longer in engineer mode.

Remote Access Programming

  • Go to ‘set up downloading’
  • Select download by (WebWayOne)
  • Select poll timeout <10>
  • Select modem init timeout <060>
  • Select rings to answer <1>
  • Select comm. Tx timeout <030>
  • Select ARMPC telephone number (not required)
  • Select program PCs <1>
  • Select modem telephone number (not required)
  • Select signal alarms (No)
  • Select signal faults (No)
  • Select signal set/unset (No)
  • Select signal access code (No)
  • Select password (optional UDL password)
  • Select redials <03>

  • Select time out <00>
  • Select stop on success (No)
  • Select dial mode (retry same)
  • Exit engineering mode and save the configuration

UDL information for this item can be found here: