WebWayWorld Logo 2018

 

Guardall Guardstation

This UDL uses virtual serial ports as the communication interface to the RM. Once you have created two serial ports virtually linked, the UDL must be configured to open one port and an Remote Manager session configured to open the other port for communications to be successful.

Create an Remote Manager Guardall GuardStation session

1)   Click on the [Sessions] menu item and select the [New] menu item. Remote Manager will display a new [Session Configuration] page.


 

2)   Give the new session a name by entering a name in the [Session Name] edit box.

3)   Then click on the [Session Type] drop down list box and select PX500 or QX34 from the list.

4)   Click on the [SSH Server 1 IP] edit box and enter the IP address of PC that is running the SSH Server and WebWayOne’s Gateway application. Do the same for [SSH Server 2 IP] .


 

5)    Click on the [Save] button. Click on the [Modify] button and the [Edit properties] button. The following form will be displayed.


 

You may need to change the COM port to one of the virtual serial ports you created and selected for the RM to listen on. COM10 is the default port for all session using serial interfaces.

Note:  You can use the same virtual serial ports for all your different UDL connections, but if you wish to use more than one UDL at the same time, you must set the COM ports for each session to be different.

6)   Click on the [Accept] button.

7)   On the main display, click on the [Save] button. This session is now ready to run.


Create an account in the Guardall’s GuardStation UDL

1)   Open up the GuardStation UDL application and enter your username and password. Click on the [Tools] menu and then on the [View Setup] menu item. A form will be displayed that has many tabs. Click on the [Comms] tab as shown below:

 

2)    You now need to configure a communications route to Remote Manager. Along [Route 1] select the [Device Type] “modem”, then select the virtual com port you have assigned to GuardStation. Select the [Baud Rate] (Default:9600).

3)     It is critical that the [Authentication Code] field is set to ‘0’ as we do not support authentication codes.



4)    Now click on the [Modem] tab and select “Modem” from the [Modem List]. Change the [Modem Control Strings] to be the same as shown in the form below:

 

 

5)     Now click on the [Call Monitor] tab and select\check the [Check for Online Events] tick box


 

6)   Click [OK] when finished.

7)   You now need to create or modify an existing customer account to be able communicate via Remote Manager. The important settings to configure are shown in the next form:


 

The [GSR ID] contains the unique identifier (account\site ID) of the panel. This will normally match the account\site ID of the WebWayOne Communicator.

The [Primary Number] contains the telephone number GuardStation will dial to contact the panel. This must be the same as the [GSR ID].

The [Primary Route] must be set to the route you configured earlier.

Support

Knowledge Base

Panel Guides

Downloads

FAQs