WebWayWorld Logo 2018

 

Rokonet RISCO’s Rokonet

This UDL uses virtual serial ports as the communication interface to the RM. Once you have created two serial ports virtually linked, the UDL must be configured to open one port and an RM session configured to open the other port for communications to be successful.

Create an RM RISCO’s Rokonet session

1) Click on the [Sessions] menu item and select the [New] menu item. RM will display a new [Session Configuration] page.



2) Give the new session a name by entering a name in the [Session Name] edit box.
3) Then click on the [Session Type] drop down list box and select Risco from the list.
4) Click on the [SSH Server 1 IP] edit box and enter the IP address of PC that is running the SSH Server and WebWayOne’s Gateway application.
Do the same for [SSH Server 2 IP].



5) Click on the [Save] button. Click on the [Modify] button and the [Edit properties] button. The following form will be displayed.



You may need to change the COM port to one of the virtual serial ports you created and selected for the RM to listen on. COM10 is the default port for all session using serial interfaces.
Note: You can use the same virtual serial ports for all your different UDL connections, but if you wish to use more than one UDL at the same time, you must set the COM ports for each session to be different.

6) Click on the [Accept] button.
7) On the main display, click on the [Save] button. This session is now ready to run.

Modify com0com configuration to work with RISCO’s Rokonet UDL

1) Open up com0com setup program.

Note: Each virtual COM port has its own pins and you can create or move links between RED and GREEN dots\pins.

The rules are:

a) One green pin can be wired/linked to one red pin,
b) One red pin can be wired/linked to multiple green pins.
c) Double click on a green pin to add/remove inverters.


2) Rewire your first and second COM ports DCD green pin link to the red ON (high) pin.







3) Then double click both DCD pins to add inverters so that both DCD pins remain always OFF (low).



4) Mouse click on [Apply] when finished configuring.

Create an account in the RISCO’s Rokonet UDL

1) Open up the Rokonet UDL application and enter your password. Click on the [Options] and then on the [System Configuration] menu item.



2) Modify the [Remote COM Port (modem)] to the virtual COM port you have assigned to this UDL.
3) Select “Hayes Optima 56K V.90 Ext” as the [Modem Type].
4) Insert “AT” into [User Modem String] and Click on [OK] when you have finished.
5) Select your panel type from the [Panel] list.
6) Click on the [Clients] menu and select the [New Client] menu item.



7) Insert your Account/Site ID into [Panel phone].
8) Rename your [Account].
9) Select the either [Fast Remote] or [Remote] from [Connection Type].
10) When you have finished with your details, click on [Clients] menu and select the [Save Client] menu item.



Support

Knowledge Base

Panel Guides

Downloads

FAQs