This UDL uses virtual serial ports as the communication interface to the RM. Once you have created two serial ports virtually linked, the UDL must be configured to open one port and an RM session configured to open the other port for communications to be successful.
2) Give the new session a name by entering a name in the [Session Name] edit box.
3) Then click on the [Session Type] drop down list box and select a Cooper Panel type like Scantronic 95 or M1000 or TS690 from the list.
4) Click on the [SSH Server IP] edit box and enter the IP address of PC that is running the SSH Server and WebWayOne’s Gateway application.
5) Click on the [Save] button. Click on the [Modify] button and the [Edit properties] button. The following form will be displayed.
You may need to change the COM port to one of the virtual serial ports you created and selected for the RM to listen on. COM10 is the default port for all session using serial interfaces.
Note: You can use the same virtual serial ports for all your different UDL connections, but if you wish to use more than one UDL at the same time, you must set the COM ports for each session to be different.
6) Click on the [Accept] button.
7) On the main display, click on the [Save] button. This session is now ready to run.
Create an account in the Cooper Security UDL
1) Open up the Downloader application and enter your user name and password. Click on [Setup] and then on [Communications]. The following form will be displayed:
2) Make sure you select your chosen virtual serial port from the [Remote Port] dropdown list. Click on the [OK] button when finished.
3) Click on the [File] menu and then the [Account Manager] menu item. The following form will be displayed:
4) Click on the [New] button and follow the Database Wizard. On the second wizard page labelled [Panel], the following details must be entered: [Account Name]:- This must match the account\site ID for the panel and the WebWayOne communicator.
[Manufacturer]:- This must match the panel manufacturer.
[Alarm Panel Type]:- This must match the panel type.
[Alarm Panel Version]:- This must match the firmware version of the panel.
[Serial Number] and [Confirm]:- These must contain the serial number of the panel.
[Panel phone number]:- This is the telephone number that the UDL will use to communicate with the RM. The number used must be the account\site ID for the panel and WebWayOne communicator.
5) Click on the [Next >] button and fill in your details. Click on the [OK] on the [Finished] page when finished.