The setup of com0com is different from normal, instead of the changes to the line linkages, the default links are used.
Interface to Siemens SPC PRO: This UDL uses virtual serial ports as the communication interface to the RM. Once you have created two serial
ports virtually linked, the UDL must be configured to open one port and an RM session configured to open the other port for communications
to be successful. The connection is handled by using the site ID as the phone number to dial.
Create an RM SPC PRO session
1) Click on the [Sessions] menu item and select the [New] menu item. RM will display a new [Session Configuration] page.
2) Give the new session a name by entering a name in the [Session Name] edit box.
3) Then click on the [Session Type] drop down list box and select Siemens Modem-DCM from the list.
4) Click on the [SSH Server 1 IP] edit box and enter the IP address of PC that is running the SSH Server and WebWayOne’s MCT application.
5) Click on the [Save] button. Click on the [Modify] button and the [Edit properties] button. The following form will be displayed.
You may need to change the COM port to one of the virtual serial ports you created and selected for the RM to listen on. COM10 is the default
port for all sessions using the serial interfaces.
Note: You can use the same virtual serial ports for all your different UDL connections, but if you wish to use more than one UDL at
the same time, you must set the COM ports for each session to be different.
6) Click on the [Accept] button.
SPC PRO (UDL)
1) Run up the SPC PRO UDL application.
2) Press the [Add New] button.
3) Fill in details.
4)Input the SPT account number into the [Telephone Number 1] field.
5) When attempting a connection to a panel, select <modem> where nnnn is the SPT account number.
<br> </modem>
6) Select the correct virtual COM port in the [Comport] list and press [Connect].